Arrow® VPS Rhythm® Device with Optional TipTracker Technology

Take the guesswork out of PICC navigation and tip placement with the Arrow® VPS Rhythm® Device with optional TipTracker Technology. This easy-to-use system provides real-time visual navigation, tracing the catheter pathway on a color screen. Plus, it helps you confirm final tip placement using familiar ECG technology, helping to expedite patient therapy and eliminate the need for a confirmatory chest x-ray.1,2

  • See and adjust the location of the PICC path in real time, with the greatest range of visual tip tracking on the market
  • Designed to work with a broad range of PICC brands and sizes
  • TipTracker Stylet is also available preloaded in all lumen configurations of Arrow® PICCs
  • Confirm final tip placement using familiar ECG technology
  • With no calibration required, save time and frustration
  • Eliminate the need for confirmatory chest X-ray or fluoroscopy1,2

 

  • Clinical user captures external baseline ECG rhythm snapshot and the Device automatically switches to intravascular mode
  • T-piece and TipTracker Stylet use electromagnetic tracking to visualize the catheter pathway on the screen in real-time, enabling immediate catheter adjustments during navigation
  • As the tip of the catheter approaches the superior vena cava (SVC), ECG waveform changes
  • Clinical user captures intravascular ECG snapshots of negative P-wave deflection and maximum P-wave to ensure correct catheter placement
  • Tip Confirmation Checklist helps verify tip placement in lower 1/3 of SVC, near the CAJ, without requiring a chest X-ray or fluoroscopy1,2

 

Choose the catheter type that is right for your patient and clinical scenario. The Arrow® VPS Rhythm® Device, with optional TipTracker Technology, is compatible with a broad range of PICC brands and sizes (3 Fr. - 6 Fr. or inner lumen diameter of ≥ 0.018 in.).

For convenience and patient protection, Arrow® PICCs and Arrowg+ard Blue Advance PICCs are available preloaded with the TipTracker Stylet and are ready to use with the VPS Rhythm® Device to create a fully integrated and powerful solution that helps you quickly achieve catheter placement.

References:

  1. See the VPS Rhythm® Device Operator’s Manual or TipTracker Stylet Instructions for Use for full Indications for Use.
  2. With appropriate hospital policy and procedure in place.
  3. Average length of SVC is 7 cm. Hostetter, R. et al 2010 JAVA 15:3, 114-123
  4. Indicated for use with central lines whose tip is intended to reside in the lower 1/3 SVC.
  5. Jeon Y, et al. Transesophageal echocardiographic evaluation of ECG-guided central venous catheter placement, Canadian Journal of Anesthesia (2006) 53:10, 978-983
  6. BARD Sherlock 3CG Tip Confirmation System Standalone Instructions for Use.


Contraindication: The Arrowg+ard Blue Advance PICC is contraindicated for patients with known hypersensitivity to chlorhexidine.

For the Arrowg+ard Blue Advance PICC: No correlation between in vitro / in vivo testing methods and clinical outcomes have currently been ascertained.

Federal Law (USA) restricts these devices to sale by or on the order of a physician.

Teleflex, the Teleflex logo, Arrow, Arrowg+ard Blue Advance, TipTracker, and VPS Rhythm are trademarks or registered trademarks of Teleflex Incorporated or its affiliates, in the U.S. and/or other countries. All other trademarks are the trademarks of their respective owners. Please check your local regulatory approval status. Refer to the applicable Instructions for Use for the indications approved in your geography.

Information in this material is not a substitute for the product Instructions for Use. This document does not imply compatibility between devices. Not all products may be available in all countries. Please contact your local representative. Revised: 08/2022. ©2022 Teleflex Incorporated. All rights reserved. MC-007978 LA EN