Specialty guidewires for coronary interventions

Teleflex offers a range of guidewires to meet the needs of your complex coronary procedures.

R350 Guidewire

350 cm nitinol core for externalization

The R350 Guidewire combines a 350 cm length for externalization with a nitinol core for flexibility and kink resistance, resulting in excellent deliverability during advancement through tortuous vessels.



Designed for performance

  • Nitinol core facilitates flexibility and kink-resistance
  • 5 cm gold-plated tungsten coil for radiopacity
  • Durable, hydrophilic coating on distal 200 cm for lubricity
  • 0.013” OD for robust support during device delivery

Nitinol core for improved kink-resistance*

*All values are based on bench test data, n=5, performed by Teleflex. Comparative data may not be indicative of clinical performance.


MODEL

O.D.

LENGTH

CORE MATERIAL

HYDROPHILIC COATING LENGTH

COIL LENGTH

RADIOPAQUE TIP LENGTH

TIP SHAPE

TIP LOAD

7390

0.013”

350 cm

Nitinol

200 cm

5 cm

5 cm

Straight

3 g

Packaged in quantities of 5 units per box. Individual units are not sold separately.

Spectre Guidewire

At the core of performance — The 0.014” workhorse powerhouse

The Spectre Guidewire dual-core design offers an ideal combination of trackability, torque control and kink resistance for a high-performance guidewire with excellent deliverability.


Dual-core for ideal control

  • Proximal stainless steel core combines pushability with support for optimal device delivery
  • Planar surfaces of proximal stainless steel and distal nitinol cores are welded without protrusions or depressions providing excellent torque transmission
  • Tapered core extends to tip for added durability and tactile response
  • Distal nitinol core is highly flexible and kink-resistant for increased durability
  • Distal coil spacing for added flexibility

Peak Track Force Comparison: Spectre Guidewire vs. Runthrough® NS Extra Floppy Guidewire

*All values are based on bench test data, n=6, performed by Teleflex. Refers to average peak force at a specific distance during trackability testing on simulated anatomy fixture. Bench testing results may not be indicative of clinical performance.

MODEL

SHAFT O.D.

DISTAL TIP O.D.

LENGTH

CORE MATERIAL

HYDROPHILIC COATING LENGTH

COIL LENGTH

RADIOPAQUE TIP LENGTH

TIP SHAPE

TIP LOAD

7386

0.014”

0.014”

200 cm*

Stainless Steel-Nitinol

42 cm

25 cm

3 cm

Straight

0.9 g

7387

0.014”

0.014”

300 cm

Stainless Steel-Nitinol

42 cm

25 cm

3 cm

Straight

0.9 g

Packaged in quantities of 5 units per box. Individual units are not sold separately.
*190 cm was a previous length that may still be in distribution in select geographies.

Bandit Guidewire

Outrun Complex Lesions

The Bandit Guidewire is a low-tip load, tapered, polymer-jacketed specialty wire designed for precise wire techniques and serves as a frontline guidewire when navigating complex lesions.


  • The Bandit Guidewire has 33.6% better torque response than the Fielder XT Guidewire2
  • The Bandit Guidewire hydrophilic coating is 36.7% more lubricious and 27.6% more durable than the Fielder XT Guidewire2,3
  • 0.008” tapered tip
  • 17 cm polymer jacket with hydrophilic coating with a stainless steel core (core-to-tip)

MODEL

SHAFT O.D.

DISTAL TIP O.D.

LENGTH

CORE MATERIAL

POLYMER JACKET LENGTH

HYDROPHILIC COATING LENGTH

COIL LENGTH

RADIOPAQUE TIP LENGTH

TIP SHAPE

TIP LOAD

7444

0.014”

0.008”

200 cm

Stainless Steel

17 cm

17 cm

16 cm

10 cm

Straight

0.8 g

7445

0.014”

0.008”

300 cm

Stainless Steel

17 cm

17 cm

16 cm

10 cm

Straight

0.8 g

Packaged in quantities of 5 units per box. Individual units are not sold separately.

  1. Penetration power refers to the labeled tip load divided by the cross sectional area of the tip.
  2. All values are based on bench test data, n=15, performed by Teleflex. All values are analyzed with 95% confidence as a percentage of means. Bench test results may not be indicative of clinical performance.
  3. Durability refers to lubricity as measured over time (25 cycles).

Raider Guidewire

The clear choice for unclear paths

The Raider Guidewire is a mid-tip load, non-tapered, polymer jacketed specialty wire with a unique tip designed to meet the demands of complex lesions and precise wire techniques.


Unmatched visibility

The Raider Guidewire features a 10 cm radiopaque tip compared to the Pilot 200 Guidewire’s 3 cm radiopaque tip. The Raider Guidewire’s extended radiopaque tip length is designed to promote precise positioning under fluoroscopy.

Superior tip load and penetration power

The Raider Guidewire is designed with a tip load and penetration power to stand up to tougher occlusions.2

Lubricious coating

More durable and lubricious than Pilot 200 Guidewire,4 the Raider Guidewire coating is designed to minimize friction during prolonged cases.

Competitive support profile

The Raider Guidewire provides a support profile designed for complex wire techniques.

MODEL

SHAFT O.D.

DISTAL TIP O.D.

LENGTH

CORE MATERIAL

POLYMER JACKET LENGTH

HYDROPHILIC COATING LENGTH

COIL LENGTH

RADIOPAQUE TIP LENGTH

TIP SHAPE

TIP LOAD

7448

0.014”

0.014”

200 cm*

Stainless Steel

30 cm

30 cm

25 cm

10 cm

Straight

4 g

7449

0.014”

0.014”

300 cm

Stainless Steel

30 cm

30 cm

25 cm

10 cm

Straight

4 g

*190 cm was a previous length that may still be in distribution in select geographies.
Packaged in quantities of 5 units per box. Individual units are not sold separately.

  1. Based on manufacturer-reported radiopaque coil lengths—Pilot 200 Guidewire labeling.
  2. All values are based on bench test data, n = 15, performed by Teleflex. Bench test results may not be indicative of clinical performance.
  3. Penetration power refers to the tested tip load divided by the cross-sectional area of the distal tip.
  4. All values are based on bench test data and are analyzed with 95% confidence as a percentage of the means. Bench test results may not be indicative of clinical performance.
  5. Durability refers to lubricity as measured over time (25 cycles tested).

Warrior Guidewire

Put the Power in Your Hands

The Warrior Guidewire is designed with a 14 g tip load, so you can rise to complex challenges with power, command and control.


  • The Warrior Guidewire has excellent torque response and high tip load consistent with the Hornet 14 Guidewire.2,3
  • 0.009” tapered tip with 14 g tip load
  • Distal 20 cm hydrophilic coating
  • Stainless steel core (core-to-tip)

MODEL

SHAFT O.D.

DISTAL TIP O.D.

LENGTH

CORE MATERIAL

HYDROPHILIC COATING LENGTH

COIL LENGTH

RADIOPAQUE TIP LENGTH

TIP SHAPE

TIP LOAD

7388

0.014”

0.009”

200 cm

Stainless Steel

20 cm

20 cm

2.5 cm

Straight

14 g

7389

0.014”

0.009”

300 cm

Stainless Steel

20 cm

20 cm

2.5 cm

Straight

14 g

Packaged in quantities of 5 units per box. Individual units are not sold separately.

  1. Penetration power refers to the labeled tip load divided by the cross sectional area of the tip.
  2. Based on bench test data, n=10, and analyzed with 95% confidence as a percentage of the means. Bench test results may not be indicative of clinical performance.
  3. Based on manufacturer reported tip load - Hornet 14 Guidewire labeling.

The R350 guidewire is indicated for use in percutaneous procedures to introduce and position catheters and other interventional devices within the coronary and/or peripheral vasculature.

The Spectre Guidewire is intended for use in percutaneous procedures to introduce and position catheters and other interventional devices within the coronary and peripheral vasculature.

The Bandit Guidewire is intended for use in percutaneous procedures to introduce and position catheters and other interventional devices within the coronary and peripheral vasculature.

The Raider Guidewire is intended for use in percutaneous procedures to introduce and position catheters and other interventional devices within the coronary and peripheral vasculature.

The Warrior Guidewire is intended for use in percutaneous procedures to introduce and position catheters and other interventional devices within the coronary and peripheral vasculature.

Refer to the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions. Information in this material is not a substitute for the product Instructions for Use.

CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.
Not all products are available in all regions. Please contact customer service to confirm availability in your region.

Teleflex, the Teleflex logo, Bandit, R350, Raider, Spectre and Warrior are trademarks or registered trademarks of Teleflex Incorporated or its affiliates, in the U.S. and/or other countries. All other trademarks and registered trademarks are property of their respective owners. MC-004143 Rev 2
Revised: 09/2020.