Intra-Aortic Balloon Pumps


AutoCAT2WAVE® IABP

ProActive CounterPulsation® Technology featuring the unique WAVE® Algorithm

The AutoCAT2WAVE® IABP relies on a unique combination of FiberOptix® Sensor Technology, aortic flow timing, proprietary WAVE® Software and the AutoPilot® Mode of operation to achieve its high level of performance — even in patients with severe arrhythmias.

  • Speed-of-light AP signal transmission overcomes delays of fluid-filled systems1,2
  • Reliably anticipates and determines AV closure — before it occurs3,4,5
  • 98% percent timing accuracy within 12 milliseconds (ms) — even during severe arrhythmias4
  • WAVE® Algorithm sets inflation point within the beat, even during arrhythmias3,4,5
  • Increases time for coronary perfusion and decreases afterload6
  • AutoPilot® Mode delivers simple, touch-of-a-button monitoring of, and response to, physiologic conditions for consistent triggering and timing

AutoCAT® 2 IABP

Designed to deliver reliability and ease of use

AutoCAT® 2 IABP relies on the AutoPilot® Mode of operation to achieve its high level of performance.

  • Automatically selects ECG/AP signal, sources, trigger mode, and timing method as well as timing settings
  • Automatically changes settings to optimize assist
  • Proprietary software sets timing to correspond to individual patient needs
  • Proprietary deflation timing management
  • AutoPilot® Mode delivers simple, touch-of-a-button monitoring of, and response to, physiologic conditions for consistent triggering and timing

AERO® AutoCAT2WAVE® IABP

Designed for air transport

  • Total fly weight is 91.5 lbs for AERO® AutoCAT2WAVE® IABP
  • Removable, low-profile control and display unit for easy viewing and pump operation
  • Designed with all the features of the AutoCAT2WAVE® IABP, but with a smaller footprint for transport
  • Conveniently located handles for moving and lifting

AERO® AutoCAT® 2 IABP

Simply unplug and go

  • No reconfiguration needed for transport
  • AutoPilot® Mode delivers simple, touch-of-a-button monitoring of, and response to, physiologic conditions for consistent triggering and timing
  • Automatically selects best signal, optimal trigger mode and timing settings

References:

  1. Reesink K, Nagel T, Bovelander J, et al. Feasibility study of a fiber-optic system for invasive blood pressure measurements. Catheter Cardiovasc Interv. 2002;57(2):272-276. Study sponsored by Teleflex. J. Bovelander is a former employee of the study sponsor.
  2. Data on file at Teleflex. Test data may not be indicative of clinical performance.
  3. Donelli A, Jansen JRC, Hoeksel B, et al. Performance of a real-time dicrotic notch detection and prediction algorithm
    in arrhythmic human aortic pressure signals. J Clin Monit. 2002;17(3-4):181-185. Study sponsored by Teleflex.
  4. Schreuder J, Castiglioni A, Donelli A, et al. Automatic intraaortic balloon pump timing using an intrabeat
    dicrotic notch prediction algorithm. Ann Thorac Surg. 2005;79(3):1017-1022. Study sponsored by Teleflex. Dr. Schreuder was formerly a paid consultant of the study sponsor.
  5. Hoeksel S, Jansen J, Blom J, & Schreuder J,. Detection of dicrotic notch in arterial pressure signals. J Clin Monit. 1997;13(5),309-316. Study sponsored by Teleflex. Dr. Schreuder was formerly a paid consultant of the study sponsor.
  6. Schreuder J, Maisano F, Donelli A, et al. Beat-to-beat effects of intra-aortic balloon pump timing on left ventricular performance in patients with low ejection fraction. Ann Thorac Surg. 2005;79(3):872-880. Study sponsored by Teleflex. Dr. Schreuder was formerly a paid consultant of the study sponsor.
There are three primary indications for IABP use: acute coronary syndrome, cardiac and non-cardiac surgery and complications of heart failure.

Refer to the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions. Information in this material is not a substitute for the product Instructions for Use.

CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.

Teleflex, the Teleflex logo, Arrow, AC3 Optimus, AERO, AutoCAT, AutoCAT2WAVE, AutoPilot, FiberOptix and WAVE are trademarks or registered trademarks of Teleflex Incorporated or its affiliates, in the U.S. and/or other countries. MC-005075