Indicated for balloon dilation of the stenotic portion of a lower limb artery for the purpose of improving profusion.*
Up to 3.8 x faster deflation times1
Enhanced crossability2
High pushability and flexibility2
| Balloon Catheter | |
|---|---|
| Catheter Type | OTW |
| Recommended guide wire | 0.014” |
| Tip | Optimized entry profile and colored |
| Balloon material | SCP (Semi-Crystalline Polymer), controlled compliance (4 - 6%) |
| Balloon folding | 3-fold |
| Balloon coating | Hydrophilic patchwork coating |
| Balloon markers | 2 swaged markers (zero profile) |
| Sizes | ø 1.5 - 4.0 mm; L: 20 - 220 mm |
| Distal shaft | 3.1F, hydrophilic coating, coaxial design; 150 mm length (ø 1.5 / 2.0 x 20 - 100 mm); 75 mm length (ø 2.0 x 140 - 220 mm and ø 2.5 - 4.0 mm) |
| Proximal shaft | 3.9F, hydrophobic coating, coaxial design; stiffening wire |
| Usable length | 150 cm (ø 1.5 - 4.0 mm); 120 cm (ø 1.5 - 2.0 mm); 90 cm (ø 2.5 - 4.0 mm) |
| Balloon diameter x length (mm) | |||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ø 1.5 x 20-70 | ø 2.0 x 40-220 | ø 2.5 x 40-220 | ø 3.0 x 40-220 | ø 3.5 x 40-140 | ø 4.0 x 40-140 | ||||||||||||||||||||
| Nominal Pressure (NP) |
atm* | 7 | 7 | 7 | 7 | 7 | 7 | ||||||||||||||||||
| ø (mm) | 1.5 | 2.0 | 2.5 | 3.0 | 3.5 | 4.0 | |||||||||||||||||||
| Rated Burst Pressure (RBP) |
atm* | 14 | 14 | 14 | 14 | 14 | 14 | ||||||||||||||||||
| ø (mm) | 1.57 | 2.08 | 2.61 | 3.18 | 3.63 | 4.16 | |||||||||||||||||||
| *1 atm= 1.013 bar | |||||||||||||||||||||||||
| Catheter Length (cm) |
Balloon ø (mm) |
Balloon length (mm) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 20 | 40 | 70 | 100 | 140 | 180 | 220 | |||||||||||
| 4F Antegrade Approach |
120 | 1.5 | 380271 | 380277 | 380283 | - | - | - | - | ||||||||
| 120 | 2 | - | 380278 | 380284 | 380290 | 380296 | 380302 | 380308 | |||||||||
| 90 | 2.5 | - | 380279 | 380285 | 380291 | 380297 | 380303 | 380309 | |||||||||
| 90 | 3 | - | 380280 | 380286 | 380292 | 380298 | 380304 | 380310 | |||||||||
| 90 | 3.5 | - | 380281 | 380287 | 380293 | 380299 | - | - | |||||||||
| 90 | 4 | - | 380282 | 380288 | 380294 | 380300 | - | - | |||||||||
| Catheter Length (cm) |
Balloon ø (mm) |
Balloon length (mm) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 20 | 40 | 70 | 100 | 140 | 180 | 220 | |||||||||||
| 4F Crossover Approach |
150 | 1.5 | 380313 | 380319 | 380325 | - | - | - | - | ||||||||
| 150 | 2 | - | 380320 | 380326 | 380332 | 380338 | 380344 | 380350 | |||||||||
| 150 | 2.5 | - | 380321 | 380327 | 380333 | 380339 | 380345 | 380351 | |||||||||
| 150 | 3 | - | 380322 | 380328 | 380334 | 380340 | 380346 | 380352 | |||||||||
| 150 | 3.5 | - | 380323 | 380329 | 380335 | 380341 | - | - | |||||||||
| 150 | 4 | - | 380324 | 380330 | 380336 | 380342 | - | - | |||||||||