Arrow-Clark VectorFlow Hemodialysis Catheter

Designed for Performance

Designed for optimum performance, The Arrow-Clark VectorFlow Catheter is a symmetrical tip tunneled hemodialysis catheter that is designed to reduce loss of lock solution, give sustained high flows and reduce the risk of thrombus accumulation due to platelet activation resulting from shear stress. Available in both retrograde and antegrade insertion platforms, the catheter is easy to place without the need for a stylet. Catheter tip design allows for placement flexibility with minimal impact on recirculation.1, 2

  • Tip design optimizes catheter flow and minimizes recirculation
  • Sidehole design reduces the loss of lock solution2, a contributing factor in reducing the risk of thrombus adherence3
  • Catheter tip design reduces the risk of platelet damage caused by shear stress2, helping to reduce the risk of thrombus accumulation on catheter surface4

Roll over points to discover features

CATHETER MATERIAL

No stylet needed for insertion, resulting in fewer steps when compared to catheters requiring a stylet

SIDEHOLE DESIGN

Optimizes catheter flow and reduces loss of lock solution, a contributing factor in reducing risk of thrombus adherence2

MINIMAL RECIRCULATION

Deflects venous blood away from the catheter, in a direction opposite to blood entering the catheter in arterial lumen

SYMMETRICAL TIP

  • Allows for ease of placement over guidewire
  • Allows reversal of lumens without increase in recirculation2
  • Catheter tip design reduces the risk of platelet damage caused by shear stress2, helping to reduce the risk of thrombus accumulation on catheter surface4

EASY TO READ CATHETER

Information on clamp inserts

Designed for Ease of Placement

  • No stylet needed for insertion, resulting in fewer steps when compared to catheters requiring a stylet
  • Antegrade and Retrograde placement available
  • Catheter tip design allows for placement flexibility with minimal impact on recirculation1, 2

Product Comparison

Please click the (CC) button for translated subtitles.

Ordering Information

RETROGRADE

DESCRIPTION

TIP-TO-CUFF INSERTION
LENGTH (CM)

CS-15192-VFE

15 Fr. x 19 cm Retrograde Radiopaque Polyurethane Catheter

19

CS-15232-VFE

15 Fr. x 23 cm Retrograde Radiopaque Polyurethane Catheter

23

CS-15272-VFE

15 Fr. x 27 cm Retrograde Radiopaque Polyurethane Catheter

27

CS-15312-VFE

15 Fr. x 31 cm Retrograde Radiopaque Polyurethane Catheter

31

CS-15422-VFE

15 Fr. x 42 cm Retrograde Radiopaque Polyurethane Catheter

42

CS-15552-VFE

15 Fr. x 55 cm Retrograde Radiopaque Polyurethane Catheter

55

RETROGRADE HUB
REPLACEMENTS

DESCRIPTION

TIP-TO-CUFF INSERTION
LENGTH (CM)

VF-15192-E

Arrow-Clark VectorFlow

Replacement Hub for part # CS-15192-VFE (19 cm)

19

VF-15232-E

Arrow-Clark VectorFlow

Replacement Hub for part # CS-15232-VFE (23 cm)

23

VF-15272-E

Arrow-Clark VectorFlow

Replacement Hub for part # CS-15272-VFE (27 cm)

27

VF-15312-E

Arrow-Clark VectorFlow

Replacement Hub for part # CS-15312-VFE (31 cm)

31

VF-15422-E

Arrow-Clark VectorFlow

Replacement Hub for part # CS-15422-VFE (42 cm)

42

VF-15552-E

Arrow-Clark VectorFlow

Replacement Hub for part # CS-15552-VFE (55 cm)

55

ANTEGRADE

DESCRIPTION

TIP-TO-CUFF INSERTION
LENGTH (CM)

CS-15192-VFIE

15 Fr. x 19 cm Antegrade Radiopaque Polyurethane Catheter

19

CS-15232-VFIE

15 Fr. x 23 cm Antegrade Radiopaque Polyurethane Catheter

23

CS-15272-VFIE

15 Fr. x 27 cm Antegrade Radiopaque Polyurethane Catheter

27

CS-15312-VFIE

15 Fr. x 31 cm Antegrade Radiopaque Polyurethane Catheter

31

CS-15422-VFIE

15 Fr. x 42 cm Antegrade Radiopaque Polyurethane Catheter

42

CS-15552-VFIE

15 Fr. x 55 cm Antegrade Radiopaque Polyurethane Catheter

55

References:

  1. KDOQI 2006 Updates Clinical Practice Guidelines and Recommendations "Long-term catheter systems—tunneled cuffed catheters (TCCs) and tunneled port catheter systems—should have their tips within the right atrium confirmed by fluoroscopy for optimal flow."
  2. "Comparison of Symmetric Hemodialysis Catheters Using Computational Fluid Dynamics" Clark, Timothy W.I. et al., J Vasc Interv Radiol 2015; 26 (2): 252-259
  3. KDOQI Clinical Practice Guidelines and Clinical Practice Recommendations for 2006 Updates: Hemodialysis Adequacy, Peritoneal Dialysis Adequacy and Vascular Access. Am J Kidney Dis 48:S1-S322, 2006 (suppl 1).
  4. ASAIO J. 2008 ; 54(1): 64–72. doi:10.1097/MAT.0b013e31815d6898
The Arrow-Clark VectorFlow Hemodialysis Catheter is indicated for use in attaining long-term vascular access for hemodialysis and apheresis. Contraindications: The Arrow-Clark VectorFlow Hemodialysis Catheter is intended for long-term hemodialysis vascular access only and should not be used for any other purpose other than those indicated in the Instructions for Use. Do not use this catheter in patients with thrombosed vessels. Warnings: Device is Sterile, Single use: Do not reuse, reprocess or resterilize. Reuse of device creates a potential risk of serious injury and/or infection which may lead to death. Refer to package insert for complete warnings, indications, contraindications, precautions, potential complications, and Instructions for Use. VectorFlow is a trademark or registered trademark of Aegis Medical Technologies, LLC. Teleflex, Arrow and Arrow-Clark are trademarks or registered trademarks of Teleflex Incorporated or its affiliates. MCI-2020-0350